Products / Microwave Noise Meters

 →   78,33 - 178 GHz
       basic technical characteristics of amplitude, frequency
       and inserting phase fluctuation of microwave signal meters:

  PARAMETER VALUE
1   Frequency range, GHz 78,33-118,1
2   Offset frequency range, kHz 0,02 – 1000
3  

Measurement limits of amplitude noise,dBs/Hz

-140 on 1 êHz
-150 on 10 êHz
-160 on 100 êHz
4   Measurement limits of phase (frequency)
noise of sources signals, dBs/Hz
-80 on 1 êHz
-105 on 10 êHz
-130 on 100 êHz
5   Measurement limits of inserting phase noises, dBs/Hz -120 on 1 êHz
-140 on 10 êHz
-150 on 100 êHz
6   Measurement error, less than, dB ±3 on 100 êHZ
7   Input signal level, more than, dBp not less 10
8   Inserting waveguide flanges WR-10
9   Waveguide canal section, mm 2,4 õ 1,2

Fluctuation meter works in temperature range from +5 C up to +50 C, at relative humidity 50-98%, atmosphere pressure 750 30 mm of mercury.

Equipment power supply - 220V±10%, frequency 50 Hz.

Microwave measuring unit dimensions: 460x550x150 (200)mm.

Microwave measuring unite weight without packing box and spare parts - less than 16kg

Represented technical characteristics can be improved by customer’s orders.