"RVS-94P” SMART RADIOWAVE VIBRATION SENSOR
Block diagram of " RVS-94P " Microwave Smart vibration sensor
The " RVS-94P " sensor is distinguished from “RVS-36P” by the increased frequency of a probing signal and the build-in channel of measuring the microwave generator frequency, thus providing higher metrological characteristics.
Specification
| |
| Parameter |
Value |
| 1 |
|
Measurement error, not more |
1% |
| 2 |
|
Resolution |
0.03 micron |
| 3 |
|
Frequency range of vibrations measurement |
0…25 000 Hz (Any 8 intervals) |
| 4 |
|
Operating frequency of probing |
(93.00±1.00) GHz |
| 5 |
|
Probing output power |
> 6 ìW |
| 6 |
|
Digital interfaces : |
RS -485, USB |
| 7 |
|
Allowable distance up to an object |
0,2…5,0 ì |
| 8 |
|
Radiation zone diameter |
0,1…0,2 ì * |
| 9 |
|
Vibrodisplacement measurement range |
0…5 000 microns ** |
| 10 |
|
FLASH memory volume for data logging |
8 ÌB |
| 11 |
|
Supply voltage |
16…32V (220V) |
| 12 |
|
Power consumption, no more |
20 W |
| 13 |
|
Weight |
3.1kg |
| 14 |
|
Overall dimensions |
215x175x135 mm |
| 15 |
|
Measured parameters |
distance, displacement, brodisplacement, vibrovelocity, vibroacceleration |
| 16 |
|
Output analog signals: |
for dc voltage |
0…10 Â |
| for direct current (current loop) ) |
4…20 ìÀ |
| for ac voltage |
-10 …+10 Â |
| relay contact block: "Alarm " |
240Â, 10 À |
| relay contact block: "Failure" |
240Â, 1 0À |
*- depend on distance to an object
**-the range is not limited, if the digital interface is used