Parameter |
Value |
| 1 |
|
Measured parameters |
distance, displacement, brodisplacement, vibrovelocity, vibroacceleration |
| 2 |
|
Measurement error, not more |
1% |
| 3 |
|
Measurement error of vibration frequency |
not more than 0,005% |
| 4 |
|
Amplitude resolution at vibrodisplacement measurement |
for time realization |
0.03 micron |
| for amplitude spectrum |
0.001 micron |
| 5 |
|
Frequency range of vibrations measurement |
0…31250 Hz |
| 6 |
|
Operating frequency of probing |
(93.00±1.00) GHz |
| 7 |
|
Probing output power |
> 6 ìW |
| 8 |
|
Digital interfaces : |
RS -485, USB |
| 9 |
|
Allowable distance up to an object |
0.2…5 ì |
| 10 |
|
Radiation zone diameter |
0,1…0,2 ì * |
| 11 |
|
Vibrodisplacement measurement range |
Unlimited |
| 12 |
|
FLASH memory volume for data logging |
Limited by PC HDD |
| 13 |
|
Supply voltage |
16…32V (220V) |
| 14 |
|
Power consumption, no more |
30 W |
| 15 |
|
Number of "RVS-94P" sensors |
1…6 |
| 16 |
|
Measured parameters |
distance, displacement, brodisplacement, vibrovelocity, vibroacceleration
|