Products / Vector
Network Analysers
→ 0,01
- 25,86 GHz
technical characteristics:
| |
|
PARAMETER |
VALUE |
NOTE |
| 1 |
|
Working frequency range, GHz |
0,01 - 2,14
2,14 - 8,24
8,24 - 17,44
17,44 - 25,86 |
3,5/1,5; 7/3; 3,5 SMA
-//-
-//-
-//-; waveguide section 11x5,5 mm |
| 2 |
|
Basic measurement error of frequency setting:
-ordinary sweep generator, %
-synthesized sweep generator, % |
from ±0,1 up to ±0,5
not less ±0,05 |
depends on frequency range |
| 3 |
|
Measurement range VSWR;
reflection coefficient module |
1,02 - 5,0
0 - 1,0 |
up to 37,50 GHz |
| 4 |
|
Measurement range of module’s transfer
coefficient, dB, |S21| |
from +30 up to -60
from 0 up to -60 |
up to 17,44 GHz
17,44 - 25,86 GHz |
| 5 |
|
Measurement range of phase’s reflection and transfer
coefficient, degree |
from 0 up to ±180
or from 0 up to 360 |
|
| 6 |
|
Basic measurement error of module’s reflection coefficient
by VSWR<2(|Ã|<0,33) |
±0,05 |
up to 25,86 GHz |
| 7 |
|
Basic measurement error of module’s transfer coefficient,
dB |
±(0,2 +0,03 Àõ) |
up to 25,86 GHz |
| 8 |
|
Basic phase measurement error reflection coefficient/
transfer coefficient: -synthesized sweep generator, degree
-ordinary sweep generator, degree
-synthesized sweep generator, degree |
±8 / ±6
±2 / ±1 |
up to 25,86 GHz
up to 25,86 GHz |
Represented technical characteristics can be improved by customer’s orders.
|